Los rectificadores de onda completa o puente y los rectificadores de media onda se utilizan para conectar dispositivos de corriente continua a fuentes de alimentación de tensión alterna, por ejemplo, frenos electromagnéticos (serie ROBA-stop®, ROBA® quick), embragues electromagnéticos (ROBATIC®), electroimanes, electroválvulas, contactores, motores de corriente continua con protección contra arranque accidental, etc. Además de rectificar la tensión alterna de entrada, se limitan los picos de tensión que se producen al desconectar cargas inductivas y que pueden dañar el aislamiento y los contactos, y se reduce la carga de contacto.
Download catalogue
Rectificadores de frenada
Here you will get:
Tip: Click on the column that is appropriate to you to configure the product in detail.
| Size | 1 | 2 | 3 | 4 |
|---|---|---|---|---|
| max. Input voltage UAC [VAC] | 400 | 400 | 500 | 600 |
| max. Output voltage UDC [VDC] | 180 | 180 | 225 | 270 |
| Output current up to 50 °C IRMS [A] | 3,0 | 4,0 | 4,0 | 4,0 |
| Output current up to 85 °C IRMS [A] | 1,8 | 2,4 | 2,4 | 2,4 |
| max. Coil nominal capacity at 230 VAC up to 50 °C PN [W] | 312 | 416 | 416 | 416 |
| max. Coil nominal capacity at 230 VAC up to 85 °C PN [W] | 187 | 250 | 250 | 250 |
| max. Coil nominal capacity at 400 VAC up to 50 °C PN [W] | 540 | 720 | 720 | 720 |
| max. Coil nominal capacity at 400 VAC up to 85 °C PN [W] | 324 | 432 | 432 | 432 |
| max. Coil nominal capacity at 500 VAC up to 50 °C PN [W] | - | - | 900 | 900 |
| max. Coil nominal capacity at 500 VAC up to 85 °C PN [W] | - | - | 540 | 540 |
| max. Coil nominal capacity at 600 VAC up to 50 °C PN [W] | - | - | - | 1.080 |
| max. Coil nominal capacity at 600 VAC up to 85 °C PN [W] | - | - | - | 648 |
| Peak reverse voltage [V] | 2.000 | 1.600 | 2.000 | 2.000 |
| Rated insulation voltage Ueff [V] | 500 | 500 | 630 | 630 |
| Free nc terminals [n] | - | 4 | - | - |
Tip: Click on the column that is appropriate to you to configure the product in detail.
| Size | 1 | 2 |
|---|---|---|
| max. Input voltage UAC [VAC] | 230 | 230 |
| max. Output voltage UDC [VDC] | 207 | 207 |
| Output current up to 50 °C IRMS [A] | 2,5 | 2,5 |
| Output current up to 85 °C IRMS [A] | 1,7 | 1,7 |
| max. Coil nominal capacity at 115 VAC up to 50 °C PN [W] | 260 | 260 |
| max. Coil nominal capacity at 115 VAC up to 85 °C PN [W] | 177 | 177 |
| max. Coil nominal capacity at 230 VAC up to 50 °C PN [W] | 517 | 517 |
| max. Coil nominal capacity at 230 VAC up to 85 °C PN [W] | 352 | 352 |
| Peak reverse voltage [V] | 1.600 | 1.600 |
| Rated insulation voltage Ueff [V] | 320 | 320 |
| Free nc terminals [n] | - | 4 |